12.2 Data sets

Drive Functions

474

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

p0186[16] = p0186[17] = ... = p0186[23]

p0186[24] = p0186[25] = ... = p0186[31]
If this rule is not observed, alarm A07514 is output. If you need a precise representation of

the data set structure of the 611U, 32 drive data sets and 4 motor data sets must be

configured.

Examples for a data set assignment

Table 12-2 Example, data set assignment

DDS

Motor

(p0186)

Encoder 1

(p0187)

Encoder 2

(p0188)

Encoder 3

(p0189)

DDS 0

MDS 0

EDS 0

EDS 1

EDS 2

DDS 1

MDS 0

EDS 0

EDS 3

-

DDS 2

MDS 0

EDS 0

EDS 4

EDS 5

DDS 3

MDS 1

EDS 6

-

-

Copying a command data set

Set parameter p0809 as follows:
1. p0809[0] = Number of the command data set to be copied (source)
2. p0809[1] = Number of the command data to which the data is to be copied (target)
3. p0809[2] = 1
Start copying.
Copying is finished when p0809[2] = 0.

Note
In STARTER, you can copy the command data sets (Drive -> Configuration -> "Command

data sets" tab page).
You can select the displayed command data set in the relevant STARTER screens.

Copying a drive data set

Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied (target)
3. p0819[2] = 1
Start copying.
Copying is finished when p0819[2] = 0.