Vector control

4.15 Instructions for commissioning permanent-magnet synchronous motors

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

149

Temperature protection can be implemented using a temperature sensor (KTY/PTC). In

order to achieve a high torque accuracy, we recommend that a KTY temperature sensor is

used.

Table 4-5

Motor data

Parameter

Description

Remark

p0304

Rated motor voltage

If this value is not known, a "0" can also be

entered. Using this value, the stator leakage

inductance can be more precisely calculated

(p0356, p0357).

p0305

Rated motor current

-

p0307

Rated motor power

-

p0310

Rated motor frequency

-

p0311

Rated motor speed

-

If the torque constant k

T

is not stamped on the rating plate or specified in the data sheet, you

can calculate this value from the rated motor data or from the stall current I

o

and stall torque

M

o

as follows:

Q

QRP

0RWQRP

3

,

0RWQRP

PLQ

N7

QRP

V

Table 4-6

Optional data

Parameter

Description

Remark

p0314

Motor pole pair number

-

p0316

Motor torque constant

-

p0320

Motor rated magnetization

current/short-circuit current

This is used for the field weakening

characteristic

p0322

Maximum motor speed

Maximum mechanical speed

p0323

Maximum motor current

De-magnetization protection

p0325

Motor pole position information

-

p0327

Optimum motor load angle

-

p0328

PE spindle, reluctance torque

constant

-

p0329

Motor pole position identification

current

-

P0341

Motor moment of inertia

For speed controller pre-control

p0342

Ratio between the total

motor moment of inertia

-

Advertising