Designations and descriptions for motion control – Efficient Networks Siemens Sinamics S120 User Manual

Page 449

Advertising
background image

Communication PROFIBUS DP/PROFINET IO

10.3 Communications via PROFINET IO

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

449

Designations and descriptions for Motion Control

Table 10-34 Time settings and meanings

Name

Value

1)

Limit value

Description

T

DC_BASE

T_DC_BASE = 4

-

Time basis for cycle time T

DC

calculation:

T

DC_BASE

=T_DC_BASE ∙ 31.25 µs = 4 ∙ 31.25 µs =

125 µs

T

DC

T_DC_MIN = 4

T_DC_MAX = 32

T_DC_MIN ≤ T_DC ≤

T_DC_MAX

Cycle time

T

DC

= T_DC ∙ T

DC_BASE

,T_DC: Integer factor

T

DC_MIN

= T_DC_MIN ∙ T

DC_BASE

= 4∙125 µs = 500 µs

T

DC_MAX

= T_DC_MAX ∙ T

DC_BASE

= 32∙125 µs = 4 ms

T

CACF

-

CACF = 1-14

IO controller application cycle time

This is the time frame in which the IO controller application

generates new setpoints (e.g. in the position controller

cycle).

Calculation example: T

CACF

= CACF∙ T_DC=

2∙500 µs = 1 ms

T

CA_Valid

-

T

CA_Valid

< T

DC

Time, measured from the beginning of the cycle, at which

the actual values of all IO devices for the controller

application process (position control) are available.

T

CA_Start

-

T

CA_Start

> T

CA_Valid

Time, measured from the beginning of the cycle, at which

the controller application process (position control) starts.

T

IO_BASE

T_IO_BASE =

125000

Time base for T

IO_Input

, T

IO_Output

T

IO_BASE

=T_IO_BASE ∙ 1 ns= 125000 ∙ 1ns = 125 µs

T_IO_InputMIN <

T_IO_Input ≤ T_DC

Time of actual value acquisition

This is the time at which the actual values are acquired

before a new cycle starts.

T

IO_Input

= T_IO_Input ∙ T

IO_BASE

T_IO_Input: integer factor

T

IO_Input

T_IO_InputMIN = 3

T

IO_InputMIN

Minimum value for T

IO_Input

Calculation: T

IO_InputMIN

= T_IO_InputMIN ∙ T

IO_BASE

= 375 µs

T_IO_OutputMIN ≤

T_IO_Output ≤ T_DC

Time of setpoint transfer

This is the time, calculated from the beginning of the cycle,

at which the transferred setpoints (speed setpoint) are

accepted by the closed-loop control system.

T

IO_Output

= T_IO_Output ∙ T

IO_BASE

T_IO_Output: integer factor

T

IO_Output

T_IO_OutputMIN = 2

T

IO_OutputMIN

Minimum value for T

IO_Output

Calculation: T

IO_OutputMIN

= T_IO_OutputMIN ∙ T

IO_BASE

=

250 µs

Dx

Data_Exchange

This service is used to implement user data exchange

between IO controller and IO device 1 - n.

R or Rx

Processing time for speed or position controller

1) The values correspond to the device master file gsdml-v2.1-siemens-sinamics-s-cu3x0-20070615.xml

Advertising