Description of vdc_min control – Efficient Networks Siemens Sinamics S120 User Manual

Page 135

Advertising
background image

Vector control

4.9 Vdc control

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

135

Description of Vdc_min control

9GFFWUO

DFWLYH

UHJHQHUDWLYH

PRWRU

,

TVHWS

73RZHU
IDLOXUH

ZLWKRXW.,3IDXOW)

ZLWKRXWSRZHUUHVWRUHIDXOW)

3RZHUUHVWRUH

3RZHUIDLOXUH

530

Q

VHWS

$

W

U

W

W

W





9

Figure 4-14 Switching Vdc_min control on/off (kinetic buffering)

In the event of a power failure, Vdc_min control is activated when the Vdc_min switch-in level

is undershot. This controls the DC link voltage and maintains it at a constant level. The motor

speed is reduced.
When the power supply is restored, the DC link voltage increases again and Vdc_min control

is deactivated at 5 % above the Vdc_min switch-on level. The motor continues operating

normally.
If the power supply is not reestablished, the motor speed continues to drop. When the

threshold in p1257 is reached, this results in a response in accordance with p1256.
Once the time threshold (p1255) has elapsed without the line voltage being reestablished, a

fault is triggered (F07406), which can be parameterized as required (factory setting: OFF3).
The Vdc_min controller can be activated for a drive. Other drives can participate in

supporting the DC link, by transferring a scaling of their speed setpoint from the controlling

drive via BICO interconnection.

Note
You must make sure that the converter is not disconnected from the power supply. It could

become disconnected, for example, if the line contactor drops out. The line contactor should

have an uninterruptible power supply (UPS), for example.