Function modules

7.3 Extended monitoring functions

Drive Functions

224

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

7.3

Extended monitoring functions

7.3.1

Features

When the extension is activated, the monitoring functions are extended as follows:
● Speed setpoint monitoring: |n_setp| ≤ p2161
● Speed setpoint monitoring: n_set > 0
● Load monitoring

Description of load monitoring

This function monitors power transmission between the motor and the working machine.

Typical applications include V-belts, flat belts, or chains that loop around the belt pulleys or

cog wheels for drive and outgoing shafts and transfer the peripheral speeds and forces.

Load monitoring can be used here to identify blockages in the working machine and

interruptions to the power transmission.
During load monitoring, the current speed/torque curve is compared with the programmed

speed/torque curve (p2182 to p2190). If the current value is outside the programmed

tolerance bandwidth, a fault or alarm is triggered depending on parameter p2181. The fault

or alarm message can be delayed by means of parameter p2192 to prevent false alarms

caused by brief transitional states.