Servo control

3.14 Vdc control

Drive Functions

102

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Angular commutation offset commissioning support (p1990)

The function for determining the commutation angle offset is activated via p1990=1. The

commutation angle offset is entered in p0431. This function can be used in the following

cases:
● Single calibration of the pole position for encoders with absolute information

(exception: The Hall sensor must always be mechanically adjusted.)

● Calibrating the zero mark position for fine synchronization

Table 3-15 Mode of operation of p0431

Incremental without

zero mark

Incremental with one

zero mark

Incremental with distance-

coded zero marks

EnDat absolute

encoder

C/D track

p0431

shifts the commutation

with respect to the C/D

track

p0431

shifts the commutation

with respect to the C/D

track and zero mark

Currently not available

Not permitted

Hall sensor

p0431

does not influence the

Hall sensor. The Hall

sensor must be

mechanically adjusted.

p0431

does not influence the

Hall sensor.

p0431

shifts the commutation

with respect to the zero

mark

p0431

does not influence the Hall

sensor.

p0431

shifts the commutation with

respect to the absolute

position (after two zero marks

have been passed)

Not permitted

Pole position

identification

p0431

no effect

p0431

shifts the commutation

with respect to the zero

mark

p0431

shifts the commutation with

respect to the absolute

position (after two zero marks

have been passed)

p0431

shifts the commutation

with respect to the

EnDat absolute

position

Note
When fault F07414 occurs, p1990 is automatically started; if p1980 is not equal to 99 and

p0301 does not refer to a catalog motor with an encoder that is adjusted in the factory.

3.14

Vdc control

Description

Vdc control can be activated if overvoltage or undervoltage is present in the DC link line-up.

In the line-up, one or more drives can be used to relieve the DC link. This prevents a fault

from occurring due to the DC link voltage and ensures that the drives are always ready to

use
This function is activated by means of the configuration parameter (p1240). It can be

activated if an overvoltage or undervoltage is present. The torque limits of the motors at

which the Vdc controller is active can be affected if discrepancies in the DC link voltage are

Advertising