Efficient Networks Siemens Sinamics S120 User Manual

Page 346

Advertising
background image

Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions

346

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Application class 4 (central motion control)

This application class defines a speed setpoint interface with execution of the speed control

on the drive and of the positioning control in the controller, such as is required for robotics

and machine tool applications with coordinated motions on multiple drives.
Motion control is primarily implemented by means of a central numerical controller (CNC).

The position control loop is closed via the bus. The synchronization of the position control

cycles in the control and in the closed-loop controllers in the drive requires a clock

synchronization of the kind that is provided by PROFIBUS DP and PROFINET IO with IRT.

M

M

M

$XWRPDWLRQ

7HFKQRORJ\

,QWHUSRODWLRQ
3RV&RQWURO

&ORFN

6WDWXV:RUG$FWXDO3RVLWLRQ

&RQWURO:RUG6SHHG6HWSRLQW

&ORVHG/RRS6SHHG&RQWURO

'ULYH

&ORFNV\QFKURQLVP

(QFRGHU

&ORVHG/RRS6SHHG&RQWURO

'ULYH

&ORVHG/RRS6SHHG&RQWURO

'ULYH

(QFRGHU

(QFRGHU

352),%86352),1(7

Figure 10-4 Application class 4

Dynamic Servo Control (DSC)

The PFOFIdrive profile contains the "Dynamic Servo Control" control concept. This can be

used to significantly increase the dynamic stability of the position control loop in application

class 4 with simple means.
For this purpose, the deadtime that is typical for a speed setpoint interface is minimized by

an additional measure (see also chapter "Dynamic Servo Control").

Selection of telegrams as a function of the application class

The telegrams listed in the table below (see also chapter "Telegrams and process data") can

be used in the following application classes: