Efficient Networks Siemens Sinamics S120 User Manual

Page 111

Advertising
background image

Servo control

3.16 Travel to fixed stop

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

111

Signal chart

0BOLPLW

QBVHWS

S

WRUTXH

UHGXFWLRQ

)L[HGVWRSUHDFKHG

S

7UDYHOWR

IL[HGVWRS

U

WRUTXH

OLPLWUHDFKHG

U

7RUTXH

XWLOL]DWLRQS

0BDFW

$OVRIRU352),GULYH

WHOHJUDPVWR

Figure 3-25 Signal chart for "Travel to fixed stop"

Commissioning for PROFIdrive telegrams 2 to 6

1. Activate travel to fixed stop.

Set p1545 = "1".

2. Set the required torque limit.

Example:

p1400.4 = "0" ––> upper or lower torque limit

p1520 = 100 Nm ––> effective in upper positive torque direction

p1521 = –1500 Nm ––> effective in lower negative torque direction

3. Run motor to fixed stop.