Figure 6-5 dc brake – Efficient Networks Siemens Sinamics S120 User Manual

Page 196

Advertising
background image

Basic functions

6.8 Armature short-circuit brake, internal voltage protection, DC brake

Drive Functions

196

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

the drive then returns to controlled mode. If the "flying restart" function is not active, the

drive can only be restarted from standstill without overcurrent fault.

● In V/f mode:

With the "flying restart" function activated, the converter frequency is synchronized with

the motor frequency, and the drive will then return to V/f mode. If

the "flying restart" function is not available, the drive can only be restarted from standstill

without overcurrent fault.


DC braking as fault response
If the DC brake is activated as a fault response, the motor is initially braked in field-oriented

mode along the braking ramp up to the threshold set in p1234. The slope of the ramp is

identical with that of the OFF1 ramp (parameterized using p1082, p1121). Subsequently, the

pulses are disabled for the motor demagnetizing time p0347 in order to demagnetize the

motor. The DC braking will start for the duration set in p1233.

If an encoder is used, braking will continue until the speed falls below the standstill threshold

p1226.

If no encoder is used, only the period in p1233 will be applied.

'&%5.,B%UDNH

'&%5.WLPH

'&%5.QB6WDUW

7RSXOVHLQKLELW
7RVHTXHQFHU

'&EUDNHUHDG\

&XUUHQWDFWXDOYDOXHV

7KHSDUDPHWHUVRIWKH,BPD[FXUUHQWFRQWUROOHUDUHXVHG

,BDFWDEVYDO

,BPD[B8BFWUO.S

,BPD[B8BFWUO7Q

_,BVHW_

'&EUDNHDFWLYH

)URP,



WFRQWUROOHU

0,1

,BFWUO.S

,BFWUO7Q

7RFRQWUROOHU

8BRXWSXW

7R9IFKDUDFWHULVWLF

3XOVHLQKLELW

%UDNHUHVSRQVH

_,BDFW_

QBDFW

QBVHW

%,&2 

3XOVHLQKLELW

%,&2 

$6&&RQILJ

$6&DFW

0RWWBGHPDJQHWL]H

)DXOWUHVSRQVH'&EUDNH

!7KHEUDNLQJFXUUHQWRIWKH'&EUDNHLVGHWHUPLQHGLQWKHDXWRPDWLFFDOFXODWLRQ S  
!7KHGHPDJQHWL]DWLRQWLPHLVGHWHUPLQHGLQWKHDXWRPDWLFFDOFXODWLRQ S  
!:KHQWKHVWDQGVWLOOWKUHVKROG S LVUHDFKHGWKH'&FXUUHQWLQMHFWLRQLVFDQFHOHGSUHPDWXUHO\
!7KHUVLJQDOLVVHWZKHQWKH'&EUDNHLVDFWLYH
!)RU6(592RQO\
!)RU9(&725RQO\

2))

_,BVHW_

QBDFW

QBVHW

_,BVHW_

_,BDFW_

[5730]
[6714]

Kp

Tn

p0115

r1239.10

p0347

p1234

p1233

p1232

p0347

<3>

p1232

0...10000 [A]
p1232[M] (0)

0...3600 [s]

p1233[M] (0)

20...210000 [1/min]

p1234[M] (0)

<1>

0... 3

p1231[M] (0)

(0)

p1230[C]

0...20 [s]

p0347[M] (0)

<2>

0

4

r1239.8

<4>

0.000...100000.000

p1345[D] (0.000)

0.000...50.000 [s]
p1346D] (0.030)

[8014]

t

t

t

r0068[0]

[5730][6730]

[6300]

r0072

0.000...100000.000 [V/A]

p1715[D] (0.000)

0.00...1000.00 [ms]
p1717[D] (2.00)

<5>

<5>

<6>

<6>

t

Figure 6-5

DC brake

Advertising