Reference model – Efficient Networks Siemens Sinamics S120 User Manual

Page 126

Advertising
background image

Vector control

4.5 Speed controller pre-control and reference model

Drive Functions

126

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Note
The ramp-up and ramp-down times (p1120; p1121) of the ramp function generator in the

setpoint channel should be set accordingly so that the motor speed can track the setpoint

during acceleration and braking. This ensures that speed controller pre-control is functioning

optimally.

The acceleration pre-control using a connector input (p1495) is activated by the parameter

settings p1400.2 = 1 and p1400.3 = 0. p1428 (dead time) and p1429 (time constant) can be

set for balancing purposes.

Reference model







6SHHGDFWXDOYDOXH

6SHHG

VHWSRLQW

5HIHUHQFHPRGHOದ3UHFRQWURO

'URRSIXQFWLRQ

LQMHFWLRQ

3,

6SHHG

FRQWUROOHU

7RUTXH
6HWSRLQW

.

S

7

Q

6/9&

9&

.

S

7

Q

7

L

7L

S

S

S

S

S

S

U

U

U

U

U>@

U>@

U

S

U

S

S

S

,

3

Figure 4-9

Reference model

The reference model is activated when p1400.3 = 1 and p1400.2 = 0.
The reference model is used to emulate the path of the speed control loop with a P speed

controller.
The path emulation can be set in p1433 to p1435. It is activated when p1437 is connected to

the output of model r1436.
The reference model delays the setpoint-actual deviation for the integral component of the

speed controller so that transient conditions can be suppressed.

Advertising