Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

349

3. Free telegrams (p0922 = 999)

The send and receive telegrams can be configured as required by using BICO technology

to interconnect the send and receive process data.

SERVO, TM41

VECTOR

CU_S

A_INF, B_INF,

S_INF, TB30,

TM31,

TM15DI/DO

Receive process data
DWORD

connector output

r2060[0 ... 14]

r2060[0 ... 30]

-

WORD connector

output

r2050[0 ... 15]

r2050[0 ... 31]

r2050[0 ... 4]

Binector output

r2090.0 ... 15

r2091.0 ... 15

r2092.0 ... 15

r2093.0 ... 15

r2090.0 ... 15

r2091.0 ... 15

Free binector-

connector

converter

p2080[0 ... 15], p2081[0 ... 15], p2082[0 ... 15], p2083[0 ... 15] / r2089[0 ... 3]

Send process data
DWORD

connector input

p2061[0 ... 14]

p2061[0 ... 30]

-

WORD connector

input

p2051[0 ... 18]

p2061[0 ... 31]

p2051[0 ... 14]

p2051[0 ... 4]

Free connector-

binector converter

p2099[0 ... 1] / r2094.0 ... 15, r2095.0 ... 15

Telegram interconnections

When you change p0922 = 999 (factory setting) to p0922 ≠ 999, the telegrams are

interconnected and blocked automatically.

Note
Telegrams 20, 352 are the exceptions. Here, PZD06 in the transmit telegram and PZD03 to

PZD06 in the receive telegram can be interconnected as required.

When you change p0922 ≠ 999 to p0922 = 999, the previous telegram interconnection is

retained and can be changed.

Note
If p0922 = 999, a telegram can be selected in p2079. A telegram interconnection is

automatically made and blocked. The telegram can also be extended.
This is an easy method of creating extended telegram interconnections on the basis of

existing telegrams.