background image

Extended setpoint channel

2.2 Description

Drive Functions

48

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

2.2

Description

In the extended setpoint channel, setpoints from the setpoint source are conditioned for

motor control.
The setpoint for motor control can also originate from the technology controller (see

"Technology controller").

5DPSIXQFWLRQJHQHUDWRU

0RWRUFRQWURO

6HWSRLQWFKDQQHO

6HWSRLQWVRXUFHV

6XSSUHVVLRQEDQGZLGWKV

VHWSRLQWOLPLWDWLRQ

0RWRUFRQWURO

6HUYRYHFWRU

'LUHFWLRQRIURWDWLRQOLPLWLQJ

GLUHFWLRQRIURWDWLRQFKDQJHRYHU

0DLQVXSSOHPHQWDU\VHWSRLQW

VHWSRLQWVFDOLQJ

0DLQVHWSRLQW

6XSSOHPHQWDU\

VHWSRLQW

-RJ

)LHOGEXV

6SHHG

IL[HGVHWSRLQWV

$QDORJ

LQSXWV

0RWRUL]HG

SRWHQWLRPHWHU

Figure 2-1

Extended setpoint channel

Properties of the extended setpoint channel

● Main/supplementary setpoint, setpoint scaling
● Direction of rotation limiting and direction of rotation changeover
● Suppression bandwidths and setpoint limitation
● Ramp function generator

Setpoint sources

The closed-loop control setpoint can be interconnected from various sources using BICO

technology (e.g. to p1070 CI: main setpoint (see function diagram 3030)).
There are various options for setpoint input:
● Fixed speed setpoints
● Motorized potentiometer