5 inputs/outputs, 1 overview of inputs/outputs – Efficient Networks Siemens Sinamics S120 User Manual

Page 484

Advertising
background image

Basic information about the drive system

12.5 Inputs/outputs

Drive Functions

484

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Changing scaling parameters p2000 to p2007

CAUTION

If a referenced form is selected and the reference parameters (e.g. p2000) are changed

retrospectively, the referenced values of some of the control parameters are also adjusted

to ensure that the control behavior is unaffected.

12.5

Inputs/outputs

12.5.1

Overview of inputs/outputs

The following digital/analog inputs/outputs are available:

Table 12-6 Overview of inputs/outputs

Digital

Analog

Component

Inputs

Bidirectional

inputs/outputs

Outputs

Inputs

Outputs

CU310

4

1)

4

3)

CU320

8

1)

8

2)

TB30

4

-

4

2

2

TM15

-

24

-

-

-

8

4

-

2

2

TM31

Relay outputs: 2

Temperature sensor input: 1

4

4

-

1

-

TM41

Incremental encoder emulation: 1 (see also the Function Manual)

1) Variable: floating or non-floating
2) 6 of these are "high-speed inputs"
3) 3 of these are "high-speed inputs"

Note
For detailed information about the hardware properties of I/Os, please refer to:

Reference: /GH1/ SINAMICS S120 Equipment Manual: Control Units
For detailed information about the structural relationships between all I/Os of a component

and their parameters, please refer to the function diagrams in:

Reference: /LH1/ SINAMICS S List Manual

Advertising