Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

397

Error

value

Meaning

Comment

Additional

info

0x15

Response too long

The length of the present response exceeds the maximum

transfer length.

0x16

Illegal parameter address

Impermissible or unsupported value for attribute, number

of elements, parameter number, subindex or a

combination of these.

0x17

Illegal format

Write request: illegal or unsupported parameter data

format

0x18

No. of values inconsistent

Write request: a mismatch exists between the number of

values in the parameter data and the number of elements

in the parameter address.

0x19

Drive object does not exist

You have attempted to access a drive object that does not

exist.

0x65

Presently deactivated.

You have tried to access a parameter that, although

available, is currently inactive (e.g. n control set and

access to parameter from V/f control).

0x6B

Parameter %s [%s]: no write access

for the enabled controller

0x6C

Parameter %s [%s]: unit unknown

0x6D

Parameter %s [%s]: Write access

only in the commissioning state,

encoder (p0010 = 4).

0x6E

Parameter %s [%s]: Write access

only in the commissioning state,

motor (p0010 = 3).

0x6F

Parameter %s [%s]: Write access

only in the commissioning state,

power unit (p0010 = 2).

0x70

Parameter %s [%s]: Write access

only in the quick commissioning

mode (p0010 = 1).

0x71

Parameter %s [%s]: Write access

only in the ready mode (p0010 = 0).

0x72

Parameter %s [%s]: Write access

only in the commissioning state,

parameter reset (p0010 = 30).

0x73

Parameter %s [%s]: Write access

only in the commissioning state,

Safety (p0010 = 95).

0x74

Parameter %s [%s]: Write access

only in the commissioning state, tech.

application/units (p0010 = 5).

0x75

Parameter %s [%s]: Write access

only in the commissioning state

(p0010 not equal to 0).

0x76

Parameter %s [%s]: Write access

only in the commissioning state,

download (p0010 = 29).

0x77

Parameter %s [%s] may not be

written in download.