1 automatic encoder adjustment – Efficient Networks Siemens Sinamics S120 User Manual

Page 152

Advertising
background image

Vector control

4.15 Instructions for commissioning permanent-magnet synchronous motors

Drive Functions

152

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

4.15.1

Automatic encoder adjustment

Description

The pole wheel-oriented closed-loop control of the synchronous motor requires information

about the pole wheel position angle. Automatic encoder adjustment must be used if the pole

wheel position encoders are not mechanically adjusted and after a motor encoder has been

replaced.
Automatic encoder adjustment only makes sense for encoders with absolute position

information and/or zero mark. The following encoders are supported:
● Sin/Cos encoder with A/B-, R-track as well as with A/B-, C/D-, R-track
● Resolver
● Absolute encoder (e.g. EnDat, SSI)
● Incremental encoder with zero mark

Encoder adjustment using a zero mark

If an incremental encoder with zero mark is being used, after the zero mark has been

passed, the position of the zero mark can be calibrated. Commutation with the zero mark is

activated via p0404.15.

Commissioning

Automatic encoder adjustment is activated with p1990 = 1. When the pulses are enabled the

next time, the measurement is carried-out and the angular difference determined (p1984) is

entered into p0431. For p1990 = 2 the determined angular difference (p1984) is not entered

into p0431 and has not effect on the closed-loop motor control. Using this function, the

angular difference - entered into p0431 - can be checked. For extremely high moments of

inertia, the run time can be scaled higher using p1999.

WARNING

The measurement causes the motor to rotate. The motor turns through a minimum of one

complete revolution.

Integration

Automatic encoder adjustment is integrated into the system in the following way:

Overview of key parameters (see SINAMICS S List Manual)

● p0404.15 Commutation with zero mark
● p0431 Angular commutation offset
● p1990 Encoder adjustment selection
● p1999 Angular commutation offset calibration, scaling

Advertising