12.1 Parameter

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

469

Saving parameters in a non-volatile memory

The modified parameter values are stored in the volatile RAM. When the drive system is

switched off, this data is lost.
The data has to be saved as follows in a non-volatile manner on the CompactFlash card so

that it is available the next time the drive is switched on.
● Save parameters - device and all drives

p0977 = 1; automatically reset to 0

● Save the parameters with STARTER

See "Copy RAM to ROM" function

Resetting parameters

The parameters can be reset to the factory setting as follows:
● Reset parameters - current drive object

p0970 = 1; automatically reset to 0

● Reset parameters - all parameters drive object "Control Unit"

p0009 = 30 parameter reset
p0976 = 1; automatically reset to 0

Access level

The parameters are subdivided into access levels. The SINAMICS S List Manual specifies in

which access level the parameter is displayed and can be changed. The required access

levels 0 to 4 can be set in p0003.

Table 12-1 Access levels

Access level

Remark

0 User-defined
1 Standard

Parameter from the user-defined list (p0013)
Parameters for the simplest operator functions (e.g. p1120 = ramp function

generator ramp-up time).

2 Extended

Parameters to handle the basic functions of the device.

3 Expert

Expert knowledge is already required for this parameter (e.g. knowledge

about BICO parameterization).

4 Service

Please contact your local Siemens office for the password for parameters

with access level 4 (Service). It must be entered into p3950.

Note
Parameter p0003 is CU-specific (belongs to Control Unit).