13 pole position identification, Standstill measurement, Rotating measurement – Efficient Networks Siemens Sinamics S120 User Manual

Page 98: Description

Advertising
background image

Servo control

3.13 Pole position identification

Drive Functions

98

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

5

6

0RWRU

&DEOH

/

˰6

/

YDU

6HULHVLQGXFWDQFH

5

FDEOH

0RWRU0RGXOH

S

S

S>0@

S>0@

S>0@

S>0@

S>0@

0RWN(

Figure 3-19 Equivalent circuit diagram for synchronous motor and cable

Overview of key parameters (see SINAMICS S List Manual)

● r0047 Status identification

Standstill measurement

● p1909 Motor data identification control word
● p1910 Motor data identification, stationary

Rotating measurement

● p1958 Motor data identification ramp-up/ramp-down times
● p1959 Rotating measurement configuration
● p1960 Rotating measurement selection

3.13

Pole position identification

Description

For synchronous motors, the pole position identification determines its electrical pole

position, that is required for the field-oriented control. Generally, the electrical pole position is

provided from a mechanically adjusted encoder with absolute information. In this case, pole

position identification is not required. For the following encoder properties, pole position

identification is not required:
● Absolute encoder (e.g. EnDat)
● Encoder with C/D track and pole pair number ≤ 8

Advertising