Efficient Networks Siemens Sinamics S120 User Manual

Page 527

Advertising
background image

Basic information about the drive system

12.12 System sampling times

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

527

5. For Active Line Modules (ALM) in booksize format, only a current controller sampling time

of 125.0 µs or 250.0 µs can be set.

6. For ALMs in chassis format, only a current controller sampling time of 250.0 µs or

400.0 µs / 375.0 µs (375 µs when p0092 = 1) can be set.

7. For Basic Line Modules (BLM), only a current controller sampling time of 2000 µs can be

set.

8. For Motor Modules in chassis format, a current controller sampling time of minimum 250

µs can be set (250 µs ≤ p0115[0] ≤ 500 µs).

9. For Motor Modules in blocksize format (PM340), a current controller sampling time of

62.5 µs, 125.0 µs, 250.0 µs, or 500.0 µs can be set (only pulse frequencies in multiples of

2 kHz permitted).

10. When a chassis unit is connected to a DQS, the smallest current controller sampling time

must be at least 250 µs.
Example:

Mixture of chassis and booksize units on a DQS

11. A current controller sampling time between 62.5 µs and 250.0 µs can be set for servo

drives (62.5 µs ≤ p0115[0] ≤ 250.0 µs).

12. A current controller sampling time between 250,0 µs and 500,0 µs can be set for servo

drives (250,0 µs ≤ p0115[0] ≤ 500,0 µs).

13. For servo drives with a current controller sampling time of p0115[0] = 62.5 µs, the

following applies:
– Only possible in booksize and blocksize format.
Maximum number of components/devices:
– Booksize: 2 servo with p0115[0] = 62.5 µs + Line Module (connected to another DQS)
– Blocksize: 1 servo with p0115[0] = 62.5 µs
– Booksize servo drives can be combined on one DQS with a servo with p0115[0] =

125.0 µs, but with the same quantity framework.

– A DQ hub DMC20 cannot be operated on a DQS with servo drives with p0115[0] =

62.5 µs but must be connected to a separate DQS.

14. Synchronous PROFIBUS operation (set p0092 to 1):

– Servo, vector and vector-V/f control objects must have the same current controller

sampling time.

Exception: 125.0 µs can be mixed with 62,5 µs and 125.0 µs can be mixed with

250.0 µs.

– The current controller sampling time must also be a multiple integer of 125.0 µs or

equal to 62.5 µs.

15. For vector and vector-V/f control drive types, and when using a sinusoidal filter

(p0230 > 0), it is only permissible to change the current controller sampling time of the

DO involved in multiple integer steps of the default value.

16. The following applies when using a Voltage Sensing Module (VSM):

All current controller sampling times at the DQS must be the same.

17. For 3 vector drives (speed control: r0108.2 = 1), a minimum current controller sampling

time of 375.0 µs can be set

(375.0 µs ≤ p0115[0] ≤ 500 µs).