3 jog – Efficient Networks Siemens Sinamics S120 User Manual

Page 49

Advertising
background image

Extended setpoint channel

2.3 Jog

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

49

● Jog
● Field bus

– Setpoint via PROFIBUS, for example

● Via the analog inputs of the following exemplary components:

– e.g. Terminal Board 30 (TB30)
– e.g. Terminal Module 31 (TM31)
– e.g. Terminal Module 41 (TM41)

2.3

Jog

Description

This function can be selected via digital inputs or via a field bus (e.g. PROFIBUS). The

setpoint is, therefore, predefined via p1058[D] and p1059[D].
When a jog signal is present, the motor is accelerated to the jog setpoint with the

acceleration ramp of the ramp-function generator (referred to the maximum speed p1082;

see diagram "Function chart: jog 1 and jog 2"). After the jog signal has been deselected, the

motor is decelerated via the set ramp of the ramp-function generator.

CAUTION

The jog function is not PROFIdrive compatible!

6LJQDO

-RJ

6LJQDO

212))

7RWDOVHWSRLQW

HIIHFWLYH U

-RJVHWSRLQW

$FWLYH

Figure 2-2

Function chart: jog and OFF1