Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

361

Bit

Meaning

Comments

BICO

0

The sensor for the fixed stop is inactive

4

Reserved

-

-

-

1

Jogging incremental active

5

Jogging, incremental

0

Jogging velocity active

BI: 2591

6 ...

15

Reserved

-

-

-

Note:

See also: SINAMICS S Function Manual, Function module "basic positioner"

NSOLL_A (speed setpoint A (16-bit))

● Speed setpoint with a 16-bit resolution with sign bit.
● Bit 15 determines the sign of the setpoint:

– Bit = 0 --> positive setpoint
– Bit = 1 --> negative setpoint

● The speed is normalized via p2000.

NSOLL_A = 4000 hex or 16384 dec ≐ speed in p2000

NSOLL_B (speed setpoint B (32-bit))

● Speed setpoint with a 32-bit resolution with sign bit. .
● Bit 31 determines the sign of the setpoint:

– Bit = 0 --> positive setpoint
– Bit = 1 --> negative setpoint

● The speed is normalized via p2000.

NSOLL_B = 4000 0000 hex or 1 073 741 824 dec ≐ speed in p2000

162//B$
162//B%

Q

S

KH[
KH[

Figure 10-9 Normalization of speed

Gn_STW (encoder n control word)

This process data belongs to the encoder interface.

XERR (position deviation)

The position deviation for dynamic servo control (DSC) is transmitted via this setpoint.