Details of the control connections

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

43

VO/24V

24V supply

24VDC ±10%

max. 420mA (total)

integrated
short-circuit monitoring,
limited overtemperature
and overload monitoring

Supply voltage (output) to supply
an SK 2x5E or other module with
24V.

-

40

GND/0V

Reference potential

-

43

VO/24V

24V supply

-

40

GND/0V

Reference potential

-

43

VO/24V

24V supply

-

40

GND/0V

Reference potential

-

11

10V REF

+10V
reference voltage

10V ± 0.2V

Max.
load 5mA

Only in combination with

SK TU4-24V-

For connection of potentiometer
5 -

10kΩ.

A 500Ω burden resistor for the
evaluation of 0/4 - 20mA signals is
contained in the enclosed bag.

-

14

AIN1+

Analog input

positive

0 … 10V,
Resolution: 8Bit
Accuracy: 0.2V

-

12 AGND/0V

Analog Ground

Reference potential for
analog signals

-

B1

DOUT BUS

(FOUT)

Frequency output

SPS compatible in
compliance with
EN61131-2
Low: 0V, High: 24V
Pulse frequency: ~ 1 -
32kHz

Pulses for evaluation via the digital
input function P420 [02]/[03] =
26/27 and the analog meaning in
P400 [-06]/[-07].

With the use of an SK TU4-24V-... this
outputs the setpoint value of the analog
input.

With the use of an SK TU4-POT-... this
outputs the setpoint value of the
integrated potentiometer.

P420

P400

B2

ON-L

Digital output, enable
left

Only in combination with

SK TU4-POT-

Control via "Left" key

P420

B3

ON-R

Digital output, enable
right

Only in combination with

SK TU4-POT-

Control via "Right" key

P420

40

GND/0V

Reference potential

-

Potential separation

PE

PE, Earth

Does not need to be connected.
Is already connected to the module
housing.

-

Mains connection, 100 - 240V or
380 - 500V, depending on the
module

-

L1

Mains connection

1.Phase

-

-

L2/N

Mains connection

2. Phase

-