4.2.1

SimpleBox, SK CSX-3H

This option is used as a simple parameterisation, display and control tool for the SK 2xxE frequency
inverter.

Features

4-digit, 7-segment LED display

Complete parameterisation of the frequency inverter.

Direct control of a frequency inverter

Displays

the

active

parameter

set

during

parameterisation and operation and the operating

value set in P001.

After the SimpleBox has been connected and the mains switched on, horizontal lines appear in the 4-digit
7-segment display. This display signals the operational readiness of the frequency inverter.

If a creep frequency value is pre-set in parameter P113, or a minimum frequency or setpoint value is pre-set
in P104, the display flashes with this initial value.

If the frequency inverter is enabled, the display changes automatically to the operating value selected in
parameter >Selection Display value< P001 (factory setting = current frequency).

The actual parameter set in use is shown by the 2 LEDs next to the display on the left in binary code.

NOTE

The digital frequency setpoint is factory set to 0Hz. To check whether the motor is working, a

frequency setpoint must be entered with the

/

key or a jog frequency via the

respective parameter >Jog frequency< (P113).

Settings should only be made by qualified personnel, in strict compliance with the warning
and safety information.

ATTENTION:The motor may start immediately after pressing the START key

!

NOTE

The SimpleBox cannot be used to control or parameterise the optional modules (e.g.:
SK xU4-

…)