Parameter list - inverter information (selection)

Parameter

Description

Settings / functions (selection)

P700
Actual operating
status

Display of current messages for the actual operating
status of the frequency inverter such as errors,
warnings or the cause of a switch-on block.

Selection:
Actual error (P700, [-01]
Actual warning (P700, [-02]
Reason for switch-on block (P700, [-03])

Error group:
1 / 2 = Overtemperature of inverter /
motor
3 / 4 = Overcurrent error
5 = Overvoltage error
16 = Motor phase monitoring
19…= Parameter identification error

P701
Last error

Displays the last 5 frequency inverter errors.

Selection:
Last error (P701, [ -01])
Second to last error (P701, [-02])

See P700

P707
Software version

Displays the firmware version / Inverter revision

Selection:
Software version (P707, [-01])
Revision (P707, [-02])

P708
Digital

input

status

Shows the switching status of the digital inputs.

Bit 0 = DIN 1
Bit 1 = DIN 2

P709
Analog

input

voltage

Displays the measured analog input value.

Selection input:
Poti P1 (P400, [-01]) - SK 2x5E
Poti P2 (P400, [-02]) - SK 2x5E
AIN1 (P400, [-01]) - SK 2x0E
AIN2 (P400, [-02]) - SK 2x0E
DIN 2 (P400, [-06])
DIN 3 (P400, [-07])

P719
Actual current

Displays the actual output current.

P740
Process

data

Bus In

Displays the actual control word and the setpoints.

[-01] = STW (Source P509)
[-

02…-04] SW 1…3 (Source P510[-01]

[-

11…-13] SW 1…3 (Source P510[-02]

P749
DIP switch status

Displays the actual DIP switch setting (S1).

Bit 0 = DIP switch 1
Bit 1 = DIP switch 2