background image

SK 200E Manual for frequency inverters

262

Subject to technical alterations

BU 0200 GB-4411

Display in the
SimpleBox

Error

Text in the Parameter Box

Cause

Remedy

Group

Details in
P700[-01] /
P701

E008

8.0

Parameter lost
(EEPROM - Maximum value
exceeded)

Error in EEPROM data

Software version of the stored data set not compatible with
the software version of the FI.

NOTE:

Faulty parameters are automatically reloaded
(factory setting).

EMC interferences (see also E020)

8.1

Inverter ID error

EEPROM faulty

8.2

External EEPROM error

--

8.3

EEPROM KSE error

(Customer interface incorrectly
identified (customer‟s interface
equipment))

The upgrade level of the frequency inverter was not
correctly identified.

EEPROM with a firmware status of version 1.2 or above
plugged in to an FI with older firmware status
Loss of parameters! (See also note in Section 6)

Switch mains voltage off and on again.

8.4

EEPROM internal error

(Database version incorrect)

8.7

EEPROM copy differs

E009

---

reserved