NORD Drivesystems BU0200 User Manual

Page 263

Advertising
background image

SK 200E Manual for frequency inverters

262

Subject to technical alterations

BU 0200 GB-4411

Display in the
SimpleBox

Error

Text in the Parameter Box

Cause

Remedy

Group

Details in
P700[-01] /
P701

E008

8.0

Parameter lost
(EEPROM - Maximum value
exceeded)

Error in EEPROM data

Software version of the stored data set not compatible with
the software version of the FI.

NOTE:

Faulty parameters are automatically reloaded
(factory setting).

EMC interferences (see also E020)

8.1

Inverter ID error

EEPROM faulty

8.2

External EEPROM error

--

8.3

EEPROM KSE error

(Customer interface incorrectly
identified (customer‟s interface
equipment))

The upgrade level of the frequency inverter was not
correctly identified.

EEPROM with a firmware status of version 1.2 or above
plugged in to an FI with older firmware status
→ Loss of parameters! (See also note in Section 6)

Switch mains voltage off and on again.

8.4

EEPROM internal error

(Database version incorrect)

8.7

EEPROM copy differs

E009

---

reserved

Advertising