SK 200E Manual for frequency inverters

142

Subject to technical alterations

BU 0200 GB-4411

Menu structure level

Screen layout during parameterisation

If the setting of a parameter is changed, then the value flashes until it is confirmed with the OK key. In order
to retain the default settings for the parameter being edited, both VALUE keys must be pressed
simultaneously. Even in this case, the setting must be confirmed with the OK key in order for the change to
be saved.

If the change is not to be saved, then pressing one of the SELECTION keys will call up the previously stored
value and pressing a SELECTION key again will exit the parameter.

P102

PS1

3

Acceleration time

2.90 s

ONLINE

FI

P1

E ready

NOTE:

The lower line in the display is used to display the current status of the box and the frequency
inverter being controlled.

NOTE:

Some parameters (e.g. P502) have additional array levels, in which further settings can be
made. The required array level must first be selected (see parameterisation, Section 6) and
confirmed with OK. The required parameter setting can now be made.

P502

PS1

[01]

3

Master function value

Off

ONLINE

FI

P1

E ready

Parameter set to be edited

Parameter to be edited (No.)

Parameter to be

edited (text)

Current

ParameterBox

status

Selected con-

trol medium

Active parameter set in

control object

Status of

control object

Array level of the select-

ed parameter.

e.g. [01], [02], [03]...

Current parameter

value