NORD Drivesystems BU0200 User Manual

Page 96

Advertising
background image

3 Options

BU 0200 GB-4411

Subject to technical alterations

95

Control connection details

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

44

24V

24V supply

24VDC ±25%

50 … 500mA (according
to load on the digital
output)

Supply voltage connection for the
module

-

40 GND /0V

GND
Reference potential

-

C5

DIN

Digital input

Current consumption with
30V

DC

: 13mA

24V

DC

: 10mA

15V

DC

: 5.5 mA

Switching thresholds
ON:

> approx. 8.5V

OFF: < approx. 7.5V

Digital input for DC brake switching -

B5

DOUT

Digital output

15 … 30V, 200mA, SPS-
compatible according to
EN61131-2
Low:

0V / <30mA

No current through brake
High: 24V / >70mA
Current through brake

Reporting of current status of the
mechanical brake

-

Potential isolation

79

MB+

Brake control

Voltage:
Mains

Brake

230V~

205V=

400V~

180V=

460/480V~

205V=

Current: max. 0.5A

The module SK CU4-MBR
generates an output voltage on
Terminals MB+/MB- for control of
an electromechanical brake. This
depends on the supply voltage and
the connection of the supply cable
to the one-way (L1

E

) or bridge

rectification (L1

B

) of the module.

The assignment of the correct
brake coil voltage must be taken
into account in the selection.

(NOTE: this function is identical to
P434=1)

P107*,
P114*,
P505

80

MB-

Brake control

Potential isolation

L1

E

Mains connection

1st phase

Supply voltage L1:
380V … 500V ± 10% AC,
max. 10A

Mains connection for one-way
rectification.

-

L1

E

-

L1

B

Mains connection

1st phase

Supply voltage L1:
200V … 275V ± 10% AC,
max. 10A

Mains connection for bridge
rectification.

-

L1

B

-

L2/N

Mains connection

2nd phase

Connection of 2nd phase for mains
connection L1

E

or L1

B

.

-

L2/N

-

* Recommended setting (P107/P114) for NORD brakes: BRE5, 10, 40: 0.02s / BRE 20, 60, 100, 150: 0.03s

Advertising