NORD Drivesystems BU0200 User Manual

Page 125

Advertising
background image

SK 200E Manual for frequency inverters

124

Subject to technical alterations

BU 0200 GB-4411

Control connection details

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

1

24V

2

9

10

24V supply

(Module and system bus
level)

24VDC ±20%

≈ 100 mA
reverse polarity protected


Max. permissible current
load: 500mA

Connection of supply voltage for
module and 24V source for supply
of the digital inputs (DIN1 to DIN8)

via DC/DC converter to
Terminal 11.

-

3

DIN5

Digital input 5

(I/O EtherCAT DIN5)

Low 0V ... 5V
High 15V ... 30V
R

i

= 10k

Input capacitance 10nF
Scan rate 1 ms

Inputs as per
EN 61131-2 Type 1

Each digital input has a reaction
time of 1ms.

P174

4

DIN7

Digital input 7

(I/O EtherCAT DIN7)

P174

5

DIN6

Digital input 6

(I/O EtherCAT DIN6)

P174

6

DIN8

Digital input 8

(I/O EtherCAT DIN8)

P174

7

0V

8

GND
Reference potential
for digital signals

As for terminal 15

GND for system bus and digital
inputs (DIN1 to DIN8)

via connection ofDC/DC converter
to Terminal 15

-

11 24V

12

13

24V supply

(Module and system bus
level)

As for terminal 1

Max. permissible current
load: 3A

Connection of supply voltage for
module and 24V source for supply
of the digital inputs (DIN1 to DIN8)

-

15

0V

17

18

GND
Reference potential
for digital signals

-

14

Sys+

System bus
data cable +

System bus
interface

-

16

Sys-

System bus
data cable -

-

19

DIN1

Digital input 1

(I/O EtherCAT DIN1)

Low 0V ... 5V
High 15V ... 30V
R

i

= 8.1k

Input capacitance 10nF
Scan rate 1 ms

Inputs as per
EN 61131-2

Type 1

Each digital input has a reaction
time of 1ms.

P174

20

DIN3

Digital input 3

(I/O EtherCAT DIN3)

P174

Advertising