NORD Drivesystems BU0200 User Manual

Page 112

Advertising
background image

3 Options

BU 0200 GB-4411

Subject to technical alterations

111

Connection example: SK TU4-PBR to SK 205E

NOTE

Looping of the 24V supply voltage (terminals 11/15) is in principle possible, however, a
maximum current load of 3A for the SK TU4-PBR(-

…) must not be exceeded!

Only adjacent terminals (e.g.: X5:11/12) may be used for looping.

Terminals 1/2 are preferentially for use with sensors and maximum loads of 500mA.

Detail of the M12 connections of the SK TU4-PBR-M12

The special wiring of the M12 round plug connectors enables the connection of both single and double
sensors, which are equipped with normal M12 system plugs with standard sensor/actuator wiring.

If the M12 round plug connectors
are used, the terminal block
connections for the digital inputs
(terminals 19, 20, 25, 26) must
not be used.

SK 205E…-Connection unit (SK TI4…)

SK TU4-

PBR…-Connection unit (SK TI4-TU-BUS)

Voltage

Source

24V DC

PROFIBUS
Subscriber

X-1

PROFIBUS
Subscriber

X+1

Wiring of the M12-plug
connector to

SK TU4-

…-M12

Coupling detail

Pin numbering

AS-i cable

Advertising