BU 0200 GB-4411

Terminal/

Name

Function

{Factory setting}

Data

Description / wiring suggestion

Parameter


Additionally for size 4

44

24V

24V supply

Input

24VDC … 30VDC

200mA (FU without
accessories) ... 800mA
according to load on the
inputs and outputs or
equipment with options

24VDC, max 60mA

output

voltage with use of the AS
interface

Supply voltage connection for the
FI control unit and the output
DOUT1/2

The frequency inverter (S IV) is
equipped with its own mains unit,
which if supplied with mains
voltage (L1/N or L1/L2/L3) via
terminal 43, provides a 24V DC
control voltage. However, an
external control voltage can be
supplied via terminal 44. The
frequency inverter automatically
switches over from the internal to
the external voltage supply.

-

Separate terminal block (2-pole) (see Section 2.7.4)

79

MB+

Brake control

Voltage:
Mains

Brake

230V

105V=

400V~

180V=

460/480V~

205V=

Current: max. 0.5A

The frequency inverter generates
an output voltage on Terminals
MB+/MB- for control of an electro-
mechanical brake. This depends
on the supply voltage of the SK
2x0E.

The assignment of the correct
brake coil voltage must be taken
into account in the selection.

(NOTE: this function is identical to
P434=1)

P107,
P114,
P505

80

MB-

Brake control