3 electrical data 3~230v – NORD Drivesystems BU0200 User Manual

Page 276

Advertising
background image

8 Technical data

BU 0200 GB-4411

Subject to technical alterations

275

8.3.3

Electrical data 3~230V

Size 1

Device type:

SK 2xxE… -250-323-A

-370-323-A

-550-323-A

-750-323-A

-111-323-A

Nominal motor power

(4-pole standard motor)

230V

0.25 kW

0.37 kW

0.55 kW

0.75 kW

1.1 kW

240V

1

/

3

hp

½ hp

¾ hp

1 hp

1½ hp

In

p

u

t

Mains voltage

3~ 230V

3 AC 200 ... 240V,

10%, 47 ... 63 Hz

Typical input current
at 230V

3~ rms

1.4 A

1.9 A

2.6 A

3.5 A

5.1 A

3~ FLA

1.4 A

1.9 A

2.6 A

3.5 A

5.1 A

Rec. mains fuse

1 AC

slow-acting [A]

10 A

10 A

10 A

10 A

16 A

Permissible
mains fuses (UL)

RK5 or faster

fuses,

min 230V

5.0 A

5.0 A

10 A

10 A

10 A

Bussmann

FRS-R-5

FRS-R-5

FRS-R-10

FRS-R-10

FRS-R-10

Circuit breaker*

min. 230V

5.0 A

5.0 A

10 A

10 A

10 A

O

u

tp

u

t

Output voltage

3~ 230V

3 AC 0 - Mains voltage

Nominal output
current at 230V

rms

1.7 A

2.2 A

3.0 A

4.0 A

5.5 A

Motor

Assembly**

1.7A

(45°C)

2.2A

(45°C)

3.0A

(45°C)

4.0A

(45°C)

5.5A

(45°C)

Wall-mounted**

1.7A

(45°C)

2.2A

(45°C)

3.0A

(45°C)

4.0A

4.0A

Min. braking resistor

100

100

100

100

100

Recommended braking
resistor

Section 2.3

200

200

200

200

200

Motor-mounting (ventilated), or wall mounting with SK TIE4-WMK-L-1 (ventilated)

Max. continuous power / max. continuous current:

S1-50°C 0.25kW / 1.7A 0.37kW / 2.2A

0.55kW / 3.0A 0.75kW / 4.0A 1.10kW / 5.5A

Max. permissible ambient temp. with nominal output current

S1

S3

70%ED 10min

S6

70%ED 10min (100% / 20%Mn)

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

50°C

Wall mounting (unventilated)

Max. continuous power / max. continuous current:

S1-50°C

S1-40°C

S1-30°C

0.25kW / 1.7A

0.25kW / 1.7A

0.25kW / 1.7A

0.37kW / 2.2A

0.37kW / 2.2A

0.37kW / 2.2A

0.55kW / 2.8A

0.55kW / 3.0A

0.55kW / 3.0A

0.55kW / 2.8A

0.55kW / 3.5A

0.75kW / 4.0A

0.55kW / 3.4A

0.75kW / 4.2A

0.75kW / 4.8A

Max. permissible ambient temp. with nominal output current

S1

S3

70%ED 10min

S6

70%ED 10min (100% / 20%Mn)

50°C

50°C

50°C

50°C

50°C

50°C

48°C

50°C

50°C

32°C

40°C

35°C

20°C

30°C

25°C

* Circuit Breaker (inverse time trip type) as per UL489

** FLA (S1-40 °C)

Advertising