2 parameterbox sk par-3h – NORD Drivesystems BU0200 User Manual

Page 138

Advertising
background image

4 Display and control

BU 0200 GB-4411

Subject to technical alterations

137

4.2.2

ParameterBox SK PAR-3H

This option is for simple parameterisation and control of the frequency inverter, as well as the display of current
operating settings and states.

Up to 5 FI data sets can be stored and managed, stored and transferred with this device. This enables an
efficient commissioning for serial applications.

Features of the ParameterBox

Illuminated, high resolution LCD graphics screen

Large-screen display of individual operating parameters

6 language display

Help text for error diagnosis

5 complete inverter data sets can be stored in the

memory, loaded and processed

Can be used for the simultaneous display of several operating values

Standardisation of individual operating parameters to display specific system data

Direct control of a frequency inverter

Can be used for the SK 2xxE frequency inverter and its options (field bus / IO extensions SK xU4-

…)

Information from the ParameterBox

After plugging the ParameterBox onto the frequency inverter and switching on the mains for the first time,
there is initially an enquiry as to the menu language, German or English. The required language is
confirmed by pressing OK.

Then the ParameterBox automatically carried out a

“bus scan”, during which the connected frequency

inverters are identified.

In the following display, the type of frequency inverter, its actual operating condition and the current status
can be seen.

After the inverter has been enabled, the display mode changes to the 3 current operation values (frequency,
voltage, current). The operating values displayed can be selected from a list of possible values (in the
>Display< / > Values< menu).

NOTE

The digital frequency setpoint (Jog frequency/minimum frequency) has a default setting of
0Hz. To check whether the motor is working, a frequency setpoint must be entered with the

key or a jog frequency entered via the relevant menu level >Parameterise<, >Base

parameters< and the relevant parameter >Jog frequency< (P113)..

Settings should only be made by qualified personnel, in strict compliance with the warning
and safety information.

ATTENTION:The motor may start immediately after pressing the START key

!

ATTENTION

With the use of a ParameterBox SK PAR-3H this must never be simultaneously connected to
the frequency inverter and the PC, as potential shifts may cause damage, especially to the
PC. (See also Manual BU0040)