NORD Drivesystems BU0200 User Manual

Page 267

Advertising
background image

SK 200E Manual for frequency inverters

266

Subject to technical alterations

BU 0200 GB-4411

7.2.2

Table of possible error messages in the I/O extension module

Error number

Error

Text in the Parameter Box

Cause

Remedy

Group

Details in
P170

E1000

1000

EEPROM error

EMC interference on the SPI bus

Module faulty

1030

System bus, Bus Off

Check connections and cables

Ensure 24V power supply

Check Bus master.

E2000

2000

DIP changed/fault

DIP switch configuration changed during operation

2001

DIP invalid config

"DIP invalid configuration"

Illegal DIP switch setting

Check DIP switch setting. Note coding of analog inputs and
outputs!

2010

A out fault
"Analog output fault"

Check switching of 10V reference voltage

Short circuit of analog output

Analog output overload (max. 10mA)

Calibration error (P152)

A range error has occurred during measurement
of the correction values

The measured values could not be saved in the
EEPROM

2020

Inverter does not support
SK xU4-IOE

The connected frequency inverter does not support the
IO extension.

(Fault not associated with SK 2xxE possible)

Advertising