Display

Error

Cause

Remedy

209_1

INVERTER DOES NOT RESPOND

The ParameterBox is waiting for a response from the connected frequency

inverter. The waiting time has elapsed without a response being received.

 Check the connection to the frequency inverter. The settings of the USS

parameters for the frequency inverter have been changed during
operation.

Identification errors

220

UNKNOWN DEVICE

Device ID not found. The connected inverter is not listed in the database of
the ParameterBox; no communication can be established.

 ParameterBox is too old for the FI.

 Please contact your Getriebebau Nord Representative.

221

SOFTWARE VERSION
NOT RECOGNISED

The software version was not found. The software of the connected
frequency inverter is not listed in the ParameterBox database, no
communication can be established.

 Please contact your Getriebebau Nord Representative.

222

CONFIGURATION STAGE NOT
RECOGNISED

An unknown component has been detected in the frequency inverter
(Customer interface).

 Please check the components installed in the frequency inverter

 If necessary, check the software version of the ParameterBox and the

frequency inverter.

223

BUS CONFIGURATION HAS
CHANGED

After restoring the last Bus configuration, a device is reported that is different
from the one stored. This error can only occur if the parameter >Auto. Bus
Scan< is set to OFF and another device has been connected to the
ParameterBox.

 Activate the Automatic Bus Scan function.

224

DEVICE NOT SUPPORTED

The inverter type entered in the ParameterBox is not supported!

 The ParameterBox cannot be used with this inverter.

225

THE CONNECTION TO THE
INVERTER IS BLOCKED

Access to a device that is not online (previously Time Out error).

 Carry out a bus scan via the parameter >Bus Scan< (P1001).

ParameterBox operating error

226

SOURCE AND TARGET ARE
DIFFERENT DEVICES

Copying objects of different types (from / to different inverters) is not
possible.

227

SOURCE IS EMPTY

Copying of data from a deleted (empty) storage medium

228

THIS COMBINATION IS NOT
PERMITTED

Target and source for the copying function are the same. The command
cannot be executed.

229

THE SELECTED ITEM IS EMPTY

Parameterisation attempt of a deleted storage medium

230

DIFFERENT SOFTWARE VERSIONS

Warning:

Copying objects with different software versions can cause problems when
transferring parameters.

Advertising