SK 200E Manual for frequency inverters

52

Subject to technical alterations

BU 0200 GB-4411

Terminal/

Name

Function

{Factory setting}

Data

Description / wiring suggestion

Parameter

77

SYS H

System bus +

Up to four SK 2xxE can be
operated on a single
system bus.

Address = 32 / 34 / 36 / 38

Internal FI system bus for
communication with optional
modules and other frequency
inverters.

For further details see Section 9.7.

P509/510

P514/515

78

SYS L

System bus -

79

MB+

Brake control

Voltage:
Mains

brake

115/230V

105V=

400V~

180V=

460/480V~

205V=

Current: max. 0.5A

The frequency inverter generates
an output voltage on Terminals
MB+/MB- for control of an
electromagnetic brake. This
depends on the supply voltage of
the SK 2x5E.

The assignment of the correct
brake coil voltage must be taken
into account in the selection.

(NOTE: this function is identical to
P434=1)

P107,
P114,
P505

80

MB-

Brake control


Additionally for SK 215E and SK 235E

89

VI /

24V SH

24V input for
'Safe Stop' function„

18…30V DC

at least 120-150mA

Fail-safe input

(For details, see supplementary
manual BU0230)

-

88

VI /

0V SH

Reference potential
for
'Safe Stop' function„

0V digital

Reference potential


Additionally for SK 225E and SK 235E

84

ASI+

Actuator/Sensor
interface

The simple setting is
made via DIP switch S1: 4
and 5 on the
SK 2xxE.

26.5

– 31.6V,

max. 290mA

For control of the SK 2xxE via the
simple field bus level.

In this case, only the yellow AS
interface cable can be used.
Additional supply via the black
cable is not possible.

P480
... P483

85

ASI-