Display

Error

Cause

Remedy

231

INVALID PASSWORD

Attempt to alter a parameter without a valid Box password being entered in
parameter >Box Password< P 1306.

232

BUS SCAN ONLY WHEN IN MODE:
ONLINE

A bus scan (search for a connected frequency inverter) is only possible when
in ONLINE mode.

Warnings

240

OVERWRITE DATA?

YES

NO

These warnings indicate that there is a possibly significant change which
needs additional confirmation.

Once the next procedure has been selected, it must be confirmed with the
"OK" key.

241

DELETE DATA?

YES

NO

242

MOVE SOFTWARE

VERSION?

NEXT

CANCEL

243

MOVE SERIES?

NEXT

CANCEL

244

DELETE ALL DATA?

YES

NO

Inverter control error

250

THIS FUNCTION IS NOT ENABLED

The required function is not enabled in the parameter >Interface< of the
frequency inverter.

 Change the value of the parameter >Interface< of the connected inverter

to the required function. More detailed information can be obtained from
the operating instructions for the frequency inverter.

251

CONTROL COMMAND WAS NOT
SUCCESSFUL

The control command cannot be implemented by the frequency inverter, as a
higher priority function, e.g. Quick stop or an OFF signal to the control
terminals of the frequency inverter is present.

252

CONTROL OFFLINE NOT POSSIBLE

Call up of a control function in Offline mode.

 Change the operating mode of the ParameterBox in the parameter

>Operating Mode< P1302 to Online and repeat the action.

253

ERROR ACKNOWLEDGEMENT NOT
SUCCESSFUL

The acknowledgement of an error at the frequency inverter was not
successful, the error message remains.

Error message from inverter

“ERROR NO. FROM INVERTER”

INVERTER FAULT
"INVERTER FAULT TEXT"

A fault with the number displayed has occurred in the inverter. The inverter
error number and text are displayed.