SK 200E Manual for frequency inverters

194

Subject to technical alterations

BU 0200 GB-4411

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

calculates the actual setpoint speed, so that neither of the two drives travels faster than
the guide speed in the curve.

19 = Servo mode torque, in servo mode, the motor torque can be set or limited using this

function. As of firmware version V1.3 this function is also without speed feedback,
however it can be used at a lower quality.

25 = Ratio gearing, "Gearing Transfer Factor", is a multiplier to compensate for the variable

transfer of a setpoint value.

30 = Motor temperature: enables measurement of the motor temperature with a

KTY-84 - temperature sensor (Details in Section 5.3)

33 = Set val torque

p, "Setpoint torque process controller", for even distribution of the torques

to coupled drive units (e.g.: S-roller drive). This function is also possible with the use of
ISD control.d-corr.F process

(Diameter correction frequency for PID process

controller)

35 = d-corr.torque

Diameter correction for torque)

36 = d-corr.F + Torque (Diameter correction frequency for PID process controller and torque)

*) For further details of the PI and process controller, please refer to Section 9.2.

**) The limits of these values are formed by the parameters >minimum frequency auxiliary
setpoint values< (P410) and the parameter >maximum frequency auxiliary setpoint values<
(P411), whereby the limits defined by (P104) and (P105) cannot be undershot or overshot.