8 Technical data

BU 0200 GB-4411

Subject to technical alterations

277

Size 4

Device type:

SK 2x0E…

-551-323-A

-751-323-A

-112-323-A

Nominal motor power

(4-pole standard motor)

230V

5.5 kW

7.5 kW

11.0 kW

240V

7½ hp

10 hp

15 hp

In

p

u

t

Mains voltage

3~ 230V

3 AC 200 ... 240V,

10%, 47 ... 63 Hz

Typical input current
at 230V

3~ rms

23.5 A

29.5 A

40.5 A

3~ FLA

22.5 A

28.5 A

39.0 A

Rec. mains fuse

1 AC

slow-acting [A]

35 A

50 A

50 A

Permissible
mains fuses (UL)

RK5 or faster

fuses, min. 230V

30 A

40 A

60 A

Bussmann

FRS-R-30

FRS-R-40

FRS-R-60

Circuit breaker*

min. 230V

30 A

40 A

60 A

O

u

tp

u

t

Output voltage

3~ 230V

3 AC 0 - Mains voltage

Nominal output cur-
rent at 230V

rms

23.0 A

29.0 A

40.0 A

Motor Assem-

bly**

23.0 A

29.0 A

40.0 A

Wall-mounted**

23.0 A

29.0 A

40.0 A

Min. braking resistor

30

20

15

Recommended braking
resistor

Sec. 2.3

47

47

23

Motor Assembly

Max. continuous power / max. continuous current:

S1-50℃

S1-40°C

5.5 kW / 23 A

5.5 kW / 23 A

7.5 kW / 29 A

7.5 kW / 29 A

7.5 kW / 29 A

11.0 kW / 40A

Max. permissible ambient temp. with nominal output current

S1

S3

70%ED 10min

S6

70%ED 10min (100% / 20%Mn)

50°C

50°C

50°C

50°C

50°C

50°C

42°C

44°C

44°C

Wall-mounting

Max. continuous power / max. continuous current:

S1-50°C

S1-40°C

5.5 kW / 23 A

5.5 kW / 23 A

7.5 kW / 29 A

7.5 kW / 29 A

7.5 kW / 29 A

11.0 kW / 40A

Max. permissible ambient temp. with nominal output current

S1

S3

70%ED 10min

S6

70%ED 10min (100% / 20%Mn)

50°C

50°C

50°C

50°C

50°C

50°C

42°C

44°C

44°C

* Circuit Breaker (inverse time trip type) as per UL489

** FLA (S1-40 °C)