Minimal configuration with options

In order to implement completely autonomous operation (i.e. independent of control cables etc.) a
potentiometer unit (SK CU4-POT) is required. In combination with an integrated mains unit
(SK CU4-

…-24V) a solution can be implemented with an SK 2x5E which uses only one mains cable

(1~ / 3~ according to the version), and a suitable speed and direction control can be ensured (See
connection example below).

Connection plan and parameterisation of SK CU4-POT, example




Frequency inverter
SK 2x5E-...

Con

tro

l

te

rm

in

a

l b

a

r

44
40

.
.

21
22
23
24

.
.
.






SK CU4-POT

Potentio-

meter

0-10

R/0/L

Switch

L1 - L2/N - L3

115/230/400V




24V Mains unit
SK CU4-24V-...

L1 - L2/N

115/230/400V

24V=

GND

10V=

AGND

0-10V

R

L

0-100%

1/3~ 115/230/400V + PE

Control terminal bar

44 40 44 ... 11 14 12 B1

(br)

(bl)

(br)

(bk)

(wh)

(br)

(wh)

(bl)

DIP switch settings (S1:):

DIP3 = off, DIP4 = on, DIP5 = off

or

recommended

parameter setting, S1: DIP1-8 = off:

P400 [07] = 1 P420 [02] = 2

P420 [01] = 1 P420 [03] = 26

NOTE

An 8-Bit A/D converter is integrated into mains units SK TU4-

…-24V and SK CU4-…-24V. This

makes it possible to connect a potentiometer or other analog setpoint source to the mains unit
and to transfer this to the digital input of the frequency inverter via a corresponding pulse signal.