SK 200E Manual for frequency inverters

56

Subject to technical alterations

BU 0200 GB-4411

Assembly

Mounting of the plug connector to the connection unit off the frequency inverter (SK TI4-

…) is usually only

possible with a connection adapter (connection extension SK TIE4-HAN10E).

Plug connector*

Mat. No.

Technical data

plus

SK TIE4-HAN10E

(275274100)

HAN 10E LA 2BUE

(Power output)

275135010

Add-on housing with 2-clamp lock, socket insert 10-pin.
+ PE, spring terminals, PE: Screw connection,

electrical data: 16A 500V

X

HAN 10E LE 1BUE

(Power input)

275135070

Add-on housing with 1-clamp lock, pin insert 10-pin.
+ PE, spring terminals, PE: Screw connection,

electrical data: 16A 500V

X

HAN 10E LE 2BUE

(Power input)

275135000

Add-on housing with 2-clamp lock, pin insert 10-pin.
+ PE, spring terminals, PE: Screw connection,

electrical data: 16A 500V

X

HAN 10E MA 2BUE

(Motor output)

275135020

Add-on housing with 2-clamp lock, socket insert 10-pin.
+ PE, spring terminals, PE: Screw connection,

electrical data: 16A 500V

X

HQ8 LA

(Power output)

275135040

Add-on housing, socket insert 8-pin. + PE, crimp
connection,

electrical data: 16A 500V

X

HQ8 LE

(Power input)

275135030

Add-on housing, pin insert 8-pin. + PE, crimp connection,

electrical data: 16A 500V

X

HQ8 MA

(Motor output)

275135050

Add-on housing, socket insert 8-pin. + PE, crimp
connection,

electrical data: 16A 500V

X

Connection extension
HAN Q5

(Power input + motor
or power output)

275274110

2 x add-on housing on a connector frame, each with one
5-pin pin insert + PE and a 5-pin socket insert + PE,
crimp

connection,

PE:

Screw

connection,

electrical data: 16A, 230V/400V

Not required!

* Further types available on request

The connection extension

SK TIE4-HAN10E

contains all the additional elements required for the HAN 10E

and HAN Q8 versions listed above. Installation is recommended as follows. Steps 2 and 3 are not required
for plug version HAN Q5.

Step 1

Step 2

Step 3

Step 4

Step 5

Disassembly of the
2 x M25 blank plug

Put on seal

Put on adapter plate

Install the add-on
plug housing with
screws and contact
washers

Make the electrical
connections