6 Parameterisation

BU 0200 GB-4411

Subject to technical alterations

215

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P515

[-01]

...

[-03]

CAN bus address

(CAN bus address)

S

0 ... 255

dec

{ all 32

dec

}

or { all 20

hex

}

Setting of the system bus address.

[-01] = Slave address,system bus reception address

[-02] = Broadcast slave address, system bus reception address (slave)

[-03] = Broadcast master address, transmission address for system bus (master)

NOTE: If up to four SK 200E are to be linked via the system bus, the addresses must be set as follows

 FI1 = 32, FI2 = 34, FI3 = 36, FI4 = 38.

The system bus addresses should be set via the DIP switches S1:1/2 (Section 5.2.2.2).

P516

Skip frequency 1

(Skip frequency 1)

S

P

0.0 ... 400.0 Hz

{ 0.0 }

The output frequency around the frequency value (P517) set here is masked.

This range is transmitted with the set brake and acceleration ramp; it cannot be continuously
supplied to the output. Frequencies below the absolute minimum frequency should not be set.

0.0 = Off: Masking frequency inactive

P517

Skip freq. area 1

(Skip frequency area 1)

S

P

0.0 ... 50.0 Hz

{ 2.0 }

Masking range for the >Masking frequency 1< P516. This frequency value is added and
subtracted from the masking frequency.

Masking frequency range 1: P516 - P517 to P516 + P517

P518

Skip frequency 2

(Skip frequency 2)

S

P

0.0 ... 400.0 Hz

{ 0.0 }

The output frequency around the frequency value (P519) set here is masked.

This range is transmitted with the set brake and acceleration ramp; it cannot be continuously
supplied to the output. Frequencies below the absolute minimum frequency should not be set.

0.0 = Off: Masking frequency inactive

P519

Skip freq. area 2

(Skip frequency area 2)

S

P

0.0 ... 50.0 Hz

{ 2.0 }

Masking range for the >Masking frequency 2< P518. This frequency value is added and
subtracted from the masking frequency.

Masking frequency range 2: P518 - P519 to P518 + P519