Parameter management

Parameter

Setting value / Description / Note

P1201

Copy - Source

Selection of the actual source object to be copied.

In the selection list, only the frequency inverters and storage media detected during the bus
scan are shown.

Value range: FI, S1 ... S5

P1202

Copy - Target

Selection of actual target object to copy.

In the selection list, only the frequency inverters and storage media detected during the bus
scan are shown.

Value range: FI, S1 ... S5

P1203

Copy - Start

This parameter triggers a transfer process, whereby all the parameters selected in >Copy

Source< are transferred to the object specified in the >Copy

– Target< parameter.

While data is being overwritten, an information window with acknowledgement appears .
The transfer starts after acknowledgement.

P1204

Load default values

In this parameter, the default settings are written to the parameters of the selected item.

This function is particularly important when editing storage objects. It is only via this
parameter that a hypothetical frequency inverter can be loaded and edited with the
ParameterBox.

Value range: FI, S1 ... S5

P1205

Delete memory

In this parameter the data in the selected storage medium is deleted.

Value range: S1 ... S5

Options

Parameter

Setting value / Description / Note

P1301

Language

Selection of languages for operation of the ParameterBox

Available languages:

German

English

Dutch

French

Spanish

Swedish

Polish

Italian

6

Danish

4

Finnish

4

Czech

4

Russian

4

P1302

Operating mode

Selection of the operating mode for the ParameterBox

Offline:
The ParameterBox is operated autonomously. The inverter data set is not accessed. The
storage objects of the ParameterBox can be parameterised and managed.

Online:
A frequency inverter is located at the interface of the ParameterBox. The frequency inverter
can be parameterised and controlled. On switchover to the "ONLINE “ mode, a bus scan is
automatically started. The FI parameters are not yet loaded.

PC Slave:

For connection to a PC with NORDCON software installed.

P1303

Automatic bus scan

Setting the switch-on characteristics.

Off:

A bus scan is not carried out, the frequency inverters connected before the switch-off are
located after switching on.

On:

A bus scan is automatically implemented when the ParameterBox is switched on.

P1304

Contrast

Contrast setting of the ParameterBox display

Value range: 0% ... 100%; Resolution 1%

6

From firmware version V4.3 or higher, (available from about the 3rd quarter of 2011), see also parameter (1308)