4 optional locations for the "sk ti4, Adapter unit – NORD Drivesystems BU0200 User Manual

Page 27

Advertising
background image

SK 200E Manual for frequency inverters

26

Subject to technical alterations

BU 0200 GB-4411

2.1.4

Optional locations for the "SK TI4-

…" adapter unit

The above drawings indicate the different installation locations for optional modules. Option location 1 is
used for implementation of an internal bus module or an internal power supply (not SK 2x0E). An internal
brake resistor can be implemented at option location 2. External bus modules, 24 V power supplies (not
SK 2x0E) or potentiometer modules can be fitted at option location 3L or 3R. The same applies for external
braking resistors. Option locations 4 and 5 are for the mounting of M12 sockets or plugs. Locations 6, 7 and
8 for sizes 1 to 3 require an additional extension from M12 to M16 so that M12 sockets and connectors
(Section 2.8.4) can be fitted. For size 4 devices, the option locations 6 - 8 are also in M16. Only one option
per option location is possible. The preferred installation location for M12 sockets or connectors should be
4L or 4R. An additional M32 hole (option location 9) is provided for the mains connection of size 4.

4L

5L

3AL

3BL

6L

7L

8L

3L

3BR

3AR

8R

7R

6R

3R

4R

5R

2

1

Top view

View from right Size 1 to 3

View from left Size 1 to 3

View from right, Size 4

View from left, Size 4

3R

3BR

3AR

4R

5R

6R

7R

8R

9R

9L

3L

3AL

3BL

6L

7L

8L

4L

5L

Advertising