4.2 Overview of external control devices

All parameters can be easily accessed for reading or editing by means of an optional SimpleBox or
ParameterBox. The changed parameter data are stored in the non-volatile EEPROM memory. This provides
the possibility of transferring a dataset from one FI to another by plugging in the EEPROM.

In addition, up to 5 complete frequency inverter data sets can be saved in the ParameterBox and then
recalled.

The connection between the SimpleBox or ParameterBox is made with an RJ12-RJ12 cable.

Module

Description

Data

SimpleBox

Hand-held

SK CSX-3H

Used (exclusively) for commissioning,
parameterisation, configuration and control
of the frequency inverter. Storage of the
parameters is not possible.

Manual BU 0040 (www.nord.com)

4-digit, 7-segment LED display

IP20

RJ12-RJ12 cable

(for connection to FI / Option)

Part No. 275281013

ParameterBox

Hand-held

SK PAR-3H

Used for commissioning, parameterisation,
configuration and control of the frequency
inverter and its options (SK xU4-

…). Saving

of parameters is possible.

Manual BU 0040 (www.nord.com)

4 digit back-lit LCD display, keyboard

Stores up to 5 complete FI data sets

IP20

RJ12-RJ12 cable (

for connection to FI / Option)

USB-Cable

(For connection to PC)

Part No. 275281014

Mounting the control unit on the SK 2xxE:

Installation of the control unit is performed as
follows:

1. Remove the protective caps from the RJ12

connectors.

2. Connect the RJ12-RJ12 cable between the

control unit and the frequency inverter.

3. During

normal

operation

after

commissioning, it is essential to replace the
protective caps and pay attention to sealing.

4. As long as one of the protective caps is

open, take care that no dirt or moisture
enters the device.