SK 200E Manual for frequency inverters

298

Subject to technical alterations

BU 0200 GB-4411

I

Setpoint source and

setpoint selection

II

Signal processing

and ramp

III

Control and

motor model

(determination of slip)

9.11 Definition of setpoint and actual value processing (frequencies)

The frequencies used in parameters (P502) and (P543) are processed in various ways according the follow-
ing table.

Function

Name

Meaning

Output to ...

without

Right/Left

with

Slip

I

II

III

8

Setpoint frequency

Setpoint

frequency

from

setpoint source

X

1

Actual frequency

Setpoint frequency for motor
model

X

23

Actual

frequency

with slip

Actual frequency at motor

X

X

19

Setpoint frequency
master value

Setpoint frequency from
setpoint source

Master value

(free from enable correction)

X

X

20

Setpoint frequency
n R master value

Setpoint frequency from
motor model

Master value

(free from enable correction)

X

X

24

Master

value

of

actual

frequency

with slip

Actual frequency from motor
model

Master value

(free from enable correction)

X

X

X

21

Actual

frequency

without slip master
value

Actual frequency without slip

Master value

X

Advertising