SK 200E Manual for frequency inverters

214

Subject to technical alterations

BU 0200 GB-4411

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P511

USS baud rate

(USS baud rate)

S

0 ... 3

{ 3 }

Setting of the transfer rate (transfer speed) via the RS485 interface. All bus participants must
have the same baud rate setting.

0 = 4800 baud

1 = 9600 baud

2 = 19200 baud

3 = 38400 baud

P512

USS address

(USS address)

0 ... 30

{ 0 }

Setting the FI Bus address.

P513

Telegram time-out

(Telegram time out)

S

-0.1 / 0.0 /
0.1 ... 100.0 s

{ 0.0 }

If the frequency inverter is directly controlled via the CAN protocol or via RS485, this
communication path can be monitored via parameter (P513). Following receipt of a valid
telegram, the next one must arrive within the set period. Otherwise the FI reports an error and
switches off with the error message E010 >Bus Time Out<.

The inverter monitors system bus communication via parameter (P120). Therefore parameter
(P513) must usually be left in the factory setting {0.0}. Parameter (P513) must only be set to {-
,0,1} if faults detected by the optional module (e.g. communication errors on the field bus level)
are not to result in the drive unit being switched off.

0.0 =

Off: Monitoring is switched off.

-0.1 =

No error: Even if the bus module detects an error, this does

not cause the frequency inverter to be switched off.

0.1… =

On: Monitoring is activated.

P514

CAN bus baud rate

(CAN bus baud rate)

S

0 ... 7

{ 5 }

Setting of the transfer rate (transfer speed) via the system bus interface. All bus participants
must have the same baud rate setting.

Note:
Optional modules (SK xU4-

…) only operate with a transfer rate of 250kBaud. Therefore the

frequency inverter must remain at the factory setting (250kBaud).

0 = 10kBaud

1 = 20kBaud

2 = 50kBaud

3 = 100kBaud

4 = 125kBaud

5 = 250kBaud

6 = 500kBaud

7 = 1Mbaud *

*) Reliable operation cannot be guaranteed