ATTENTION

Only plug in or disconnect the the memory module from parameterisation adapter if the
connection to the PC has been disconnected! Otherwise the memory module and the
SK EPG

– 3H may be damaged. In addition, communication errors may occur during the

operation of NORD CON.

6.4.3

Parameterisation adapter LEDs

The operating status of the SK EPG-3H parame-
terisation adaptor is indicated by 2 frontmounted LEDs.

DE - red

DS - green

Meaning

Off

Off

Device

not

ready

(not

connected,

no

(Windows)

driver installed)

On

On

Boot up sequence running

Off

Flashing

(1Hz)

Device ready for operation, no
error

Flashing

(8x)

Off

Parameter loss - data transfer
to memory module has failed

6.4.4

Parameterisation adapter FAQs

Fault

Cause / Remedy

NORDCON cannot find a device

USB device driver not installed

Install driver

Wrong baud rate set in NORDCON

in Extras

→ Communication settings: set 38400 Baud

Wrong COM port selected in NORDCON

in Extras

→ Communication settings, set correct COM port

(similar to Windows

©

Device Manager

Close NORDCON and restart

SK EPG-3H and NORDCON report
"Parameter loss"

Memory module has been removed or is not correctly plugged in to the
parameterisation adapter

Disconnect SK EPG-3H from the PC, correctly insert the, memory module

and

restore the connection.

Data set in the memory module is
unchanged after writing

Memory module was not (not correctly) plugged in on boot up of the
SK EPG-3H. The parameterisation adapter functions with the internal data
memory.

Disconnect SK EPG-3H from the PC, correctly insert the, memory module

and

restore the connection.