2 general data for mains/setpoint modules – NORD Drivesystems BU0200 User Manual
Page 272

8 Technical data
BU 0200 GB-4411
Subject to technical alterations
271
8.2 General data for mains/setpoint modules
Mains/setpoint modules (SK CU4/TU4-24V-..., SK TU4-POT-...)
Function
Specification
Analog setpoint input / PI input
0/2 ... 10V, 0/4 ... 20mA (if necessary with 500Ω burden), scalable
Analog setpoint resolution
10 bit based on measurement range
Analog output
0/2 ... 10V, 0/4 ... 20mA scalable
Setpoint consistency
Analog < 1%
Digital < 0.02%
Level of radio interference suppression B
Input voltage
1~ 100V -
10% … 240V +10% (SK xU4-…-123-B)
1~ 380V -
20% … 500V +10% (SK xU4-…-140-B)
Output voltage
24V DC ± 10%
Max. permissible continuous output
current
420 mA
Protective measures against
Short circuit
Overtemperature, overload
(limited monitoring)
Long-term storage
See Section 9.12.1