NORD Drivesystems BU0200 User Manual

Page 92

Advertising
background image

3 Options

BU 0200 GB-4411

Subject to technical alterations

91

Details of the control connections

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

44

24V

24V supply

(module, system bus level)

24VDC ±20%

≈ 50mA
protected against reverse
polarity

Max. permissible current
load: 2A

Connection for module supply
voltage and 24V source for the
digital inputs (DIN1 and DIN2)

-

40

GND/0V

Reference potential
for digital signals

-

C1

DIN1

Digital input 1

(I/O CANopen DIN1)

Low 0V ... 5V

High 15V ... 30V

R

i

= 8.1k

Input capacitance 10nF

Scan rate 1 ms

Each digital input has a reaction
time of 1ms

Inputs compliant with
EN 61131-2,

Type 1

P174

C2

DIN2

Digital input 2

(I/O CANopen DIN2)

P174

77

Sys H

System bus
data cable +

System bus
interface

-

78

Sys L

System bus
data cable -

-

40

GND/0V

Reference potential
for digital signals

-

Potential separation

45

VI /

24V BUS

24V bus supply
voltage

(Field bus)

For CANopen - Bus
24VDC ±20%
≈ 50mA, protected against
reverse polarity

CANopen bus supply is essential

-

75

CAN H

(incoming)

Bus +

CAN H

RS485 transfer
technology

The use of a twisted, shielded two-
wire cable is strongly
recommended

-

76

CAN L

(incoming)

Bus -

CAN L

-

46

GND/

0V BUS

Data ground Bus

BUS reference potential

-

90

SHLD

Bus shield

-

45

VI /

24V BUS

24V bus supply
voltage

For CANopen - Bus
24VDC ±20%
≈ 50mA, protected against
reverse polarity

CANopen bus supply is essential

-

75

CAN H

(outgoing)

Bus +

CAN H

RS485 transfer
technology

The use of a twisted, shielded two-
wire cable is strongly
recommended

-

76

CAN L

(outgoing)

Bus -

CAN L

-

46

GND/

0V BUS

Data ground Bus

BUS reference potential

-