NORD Drivesystems BU0200 User Manual

Page 266

Advertising
background image

7 Status messages

BU 0200 GB-4411

Subject to technical alterations

265

Display in the
SimpleBox

Error

Text in the Parameter Box

Cause

Remedy

Group

Details in
P700[-01] /
P701

E015

15.0

reserved

E016

16.0

Motor phase error

A motor phase is not connected.

Check P539

Check motor connections

16.1

Magn Current Watch
"Magnetisation current
monitoring"

Required excitation current not achieved at moment of
switch-on.

Check P539

Check motor connections

E018

18.0

Safety circuit

The safe pulse block was triggered while the frequency
inverter was being enabled.

Only available in SK 21xE and SK 23xE. For details, please
refer to Manual BU 0230 (

www.nord.com

)

E019

19.0

Parameter ident
"Parameter identification"

Automatic identification of the connected motor was
unsuccessful

Check motor connections

Check preset motor data (P201 … P209)

19.1

Star delta

incorrect

"Motor star/delta switching
incorrect"

E020

E021

20.0

reserved

System error in program execution, triggered by EMC
interference.

Please comply with wiring guidelines in Section 2.5.

Use additional external mains filter. (Section 9.3 / 9.4 EMC)

FI must be very well earthed.

20.1

Watchdog

20.2

Stack overflow

20.3

Stack underflow

20.4

Undefined opcode

20.5

Protected Instruct.
"Protected Instruction"

20.6

Illegal word access

20.7

Illegal Inst.

Access

"Illegal Instruction Access"

20.8

Prog memory error
"Program memory error"
(
EEPROM error)

20.9

reserved

21.0

NMI error
(not used by hardware)

21.1

PLL error

21.2

ADU error

21.3

PMI error

21.4

Userstack overflow