NORD Drivesystems BU0200 User Manual

Page 124

Advertising
background image

3 Options

BU 0200 GB-4411

Subject to technical alterations

123

However, in this case it should be noted that there is an increased risk of introducing interference into the
bus cables.

Connection of up to 8 sensors and 2 actuators is made via the terminal bar.

Digital inputs

System bus level and digital inputs

Digital outputs

24V

DIN 5

DIN 6

0V

24V

(as 1)

24V

(as 1)

24V

(as 1)

0V

0V

DIN 1

0V

24V

(as 1)

DIN 2

0V

24V

(as 1)

24V2

DO 1

0V 2

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

24V

(as 1)

DIN 7

DIN 8

0V

24V

(as 1)

24V

(as 1)

Sys +

Sys -

0V

DIN 3

0V

24V

(as 1)

DIN 4

0V

24V

(as 1)

0V2

DO 2

0V 2

Connection example: SK TU4-ECT to SK 205E

NOTE

Looping of the 24V supply voltage is possible, however a maximum current load of 3A for
the SK TU4-ECT(-

…) must not be exceeded.

Only adjacent terminals (e.g.: 11/12) may be used for looping.

Terminals 1/2 are preferentially for use with sensors and maximum loads of 500mA.

Potential level: system bus

Potential level: system bus

Potential level: DOs

Illustration of the terminal bar of the bus connection
unit SK TI4-TU-BUS with allocation of functions

S

K 205E… Adapter unit (SK TI4…)

SK TU4-

ECT… Adapter unit (SK TI4-TU-BUS)

Voltage

Source

24V DC

Advertising